الصفحة الرئيسية>>Labeling & Detection>> Fluorescence>>Cal Green™ 1 AM

Cal Green™ 1 AM (Synonyms: Calcium Green-1 AM)

رقم الكتالوجGC43116

كال جرين ™ ؛ 1 صباحًا عبارة عن مؤشر كالسيوم فلوري متخلل للخلايا (إثارة 506 نانومتر ؛ انبعاث 531 نانومتر).

Products are for research use only. Not for human use. We do not sell to patients.

Cal Green™ 1 AM التركيب الكيميائي

Cas No.: 186501-28-0

الحجم السعر المخزون الكميّة
50μg
43٫00
متوفر
1mg
361٫00
متوفر

Tel:(909) 407-4943 Email: sales@glpbio.com


مراجعات العميل

بناء على آراء العملاء.

  • GlpBio Citations

    GlpBio Citations
  • Bioactive Compounds Premium Provider

    Bioactive Compounds Premium Provider

Sample solution is provided at 25 µL, 10mM.

Description of Cal Green™ 1 AM

Cal Green™ 1 AM is a cell-permeant acetyloxy-methyl ester compound that is converted to the fluorescent calcium indicator Cal Green™ 1 by intracellular esterases. This derivative is characterized by high quantum yield and low phototoxicity. Its peak excitation and emission wavelengths (506 and 531 nm, respectively) are comparable to standard fluorescein dyes, making Cal Green™ 1 AM appropriate for fluorescent microscopy and flow cytometry. Cal Green™ 1 is ~5-fold brighter than fluo-3 at saturating calcium levels.

Protocol of Cal Green™ 1 AM

This plan only provides a guide, please modify it to meet your specific needs.

1. Prepare dyeing solution

(1) Prepare stock solution: Prepare AM ester stock solution with a concentration of 1-10mM in high-quality anhydrous DMSO;

Notice:

① Aliquot the unused stock solution and store it in the dark at -20°C or -80°C to avoid repeated freezing and thawing;

② Acetoxymethyl ester (AM) easily absorbs moisture. After taking it out of the refrigerator, please bring it to room temperature in a dry environment before opening it. Please centrifuge briefly before opening to ensure the powder falls to the bottom of the tube.

(2) Prepare working solution: Dilute the stock solution with a suitable buffer (such as serum- and phenol red-free culture medium or PBS) to prepare a working solution with a concentration of 1-10μM.

Notice:

① When preparing the AM ester staining working solution, it is sometimes necessary to add an appropriate amount of 20% Pluronic F-127 solution to the stock solution to enhance the water solubility of the AM probe;

② Pluronic F-127 can prevent AM probes from aggregating in solution and promote better entry of the probe into cells. However, Pluronic F-127 can reduce the stability of the AM probe, so it is only recommended to be added when preparing the working solution. It is not recommended to add the stock solution for long-term storage;

③ Prepare 20% (w/v) Pluronic F-127 stock solution: weigh 100mg Pluronic F-127 powder (Cat. No.: GB30090), add 500μl DMSO, heat at 40-50℃ for 20-30min, and store at room temperature. If crystals precipitate, they can be reheated to dissolve without affecting use;

④ (Optional) GLPBIO provides dissolved Pluronic F-127 (20% Solution in DMSO), product number: GB30091;

⑤ Add an equal volume of 20% Pluronic F-127 solution to the stock solution so that the final working concentration of Pluronic F-127 is approximately 0.02%;

⑥ Please adjust the concentration of the working fluid according to the actual situation, and prepare it now to avoid repeated freezing and thawing.

 

2. Cell suspension staining

(1) Suspension cells: centrifuge at 4°C and 1000g for 3-5 minutes, discard the supernatant, and wash twice with PBS or other buffer, 5 minutes each time;

(2) Adherent cells: wash twice with PBS or other buffers, add trypsin to digest the cells, and centrifuge at 1000g for 3-5 minutes after digestion is completed;

(3) Add dye working solution to resuspend the cells, and incubate at room temperature or lower than room temperature in the dark for 20min-2h. The optimal incubation time for different cells is different, please explore according to your specific experimental needs;

Note:

① The recommended working concentration of AM ester dyes in most cells is 4-5μM, and the specific concentration needs to be optimized according to experimental requirements. In order to avoid cytotoxicity caused by overloading, it is recommended to use the lowest probe concentration possible based on achieving effective results;

② (Optional) If the cells contain organic anion transporters, you may need to add probenecid (GC16825, Probenecid, 1-2.5mM) or sulfinpyrazone (GC11049, Sulfinpyrazone, 0.1-0.25mM) to the cell culture medium. to reduce the leakage level of the deesterification probe. The stock solution of probenecid or sulfinpyrazone is alkaline, so the pH needs to be readjusted after adding the culture medium;

③ If serum-containing medium is used, serum lactonase will degrade AM, thereby reducing the dye loading effect; while phenol red-containing medium will make the background value slightly higher. It is recommended to wash the cells 2 to 3 times before adding the staining working solution;

④ Lowering the probe loading temperature may reduce the compartmentalization of the probe.

(4) After the incubation, centrifuge at 1000g for 5 minutes to remove the staining solution, add PBS or other buffers and wash 2-3 times to remove residual probes;

(5) Incubate at room temperature for another 30 minutes to ensure complete deesterification of intracellular AM.

 

3. Cell adhesion staining

(1) Culture adherent cells on sterile coverslips;

(2) Remove the coverslip from the culture medium, suck out the excess culture medium, and place the coverslip in a humid environment;

(3) Add 100 μL of dye working solution from one corner of the coverslip and shake gently to evenly cover all cells with the dye;

(4) Incubate in the dark at room temperature or lower than room temperature for 20min-2h. The optimal incubation time for different cells is different, please explore according to your specific experimental needs;

(5) After the incubation, discard the dye working solution and wash the coverslip 2 to 3 times with PBS or other buffers;

(6) Incubate at room temperature for 30 minutes.

 

4. Microscope detection: The maximum excitation wavelength and emission wavelength of Cal Green™ 1 AM are 488/512nm respectively.

Precautions:

1) Fluorescent dyes all have quenching problems. Please avoid light as much as possible to slow down fluorescence quenching.

2) For your safety and health, please wear a lab coat and disposable gloves.

References:

[1]. V Silei,et al. Measurement of intracellular calcium levels by the fluorescent Ca(2+) indicator Calcium-Green. 2000 Apr;5(2):132-4. doi: 10.1016/s1385-299x(00)00003-9.

Chemical Properties of Cal Green™ 1 AM

Cas No. 186501-28-0 SDF
المرادفات Calcium Green-1 AM
Canonical SMILES ClC(C(OC(C)=O)=C1)=CC2=C1OC3=C(C24C5=CC=C(C(NC6=CC=C(N(CC(OCOC(C)=O)=O)CC(OCOC(C)=O)=O)C(OCCOC7=C(N(CC(OCOC(C)=O)=O)CC(OCOC(C)=O)=O)C=CC=C7)=C6)=O)C=C5C(O4)=O)C=C(Cl)C(OC(C)=O)=C3
Formula C59H53Cl2N3O26 M.Wt 1291
الذوبان Soluble in DMSO Storage Store at -20°C
General tips Please select the appropriate solvent to prepare the stock solution according to the solubility of the product in different solvents; once the solution is prepared, please store it in separate packages to avoid product failure caused by repeated freezing and thawing.Storage method and period of the stock solution: When stored at -80°C, please use it within 6 months; when stored at -20°C, please use it within 1 month.
To increase solubility, heat the tube to 37°C and then oscillate in an ultrasonic bath for some time.
Shipping Condition Evaluation sample solution: shipped with blue ice. All other sizes available: with RT, or with Blue Ice upon request.

Complete Stock Solution Preparation Table of Cal Green™ 1 AM

Prepare stock solution
1 mg 5 mg 10 mg
1 mM 0.7746 mL 3.873 mL 7.7459 mL
5 mM 0.1549 mL 0.7746 mL 1.5492 mL
10 mM 0.0775 mL 0.3873 mL 0.7746 mL
  • حاسبة المولارية

  • حاسبة التخفيف

  • Molecular Weight Calculator

كتلة
=
تركيز
x
مقدار
x
ميغاواط *
 
 
 
** عند إعداد حلول المخزون، دائمًا استخدم الوزن الجزيئي الخاص بالدفعة للمنتج على ملصق القارورة MSDS / CoA (متوفر عبر الإنترنت).

احسب

In vivo Formulation Calculator (Clear solution) of Cal Green™ 1 AM

Step 1: Enter information below (Recommended: An additional animal making an allowance for loss during the experiment)

mg/kg g μL

Step 2: Enter the in vivo formulation (This is only the calculator, not formulation. Please contact us first if there is no in vivo formulation at the solubility Section.)

% DMSO % % Tween 80 % ddH2O
%DMSO %

Calculation results:

Working concentration: mg/ml;

Method for preparing DMSO master liquid: mg drug pre-dissolved in μL DMSO ( Master liquid concentration mg/mL, Please contact us first if the concentration exceeds the DMSO solubility of the batch of drug. )

Method for preparing in vivo formulation: Take μL DMSO master liquid, next addμL PEG300, mix and clarify, next addμL Tween 80, mix and clarify, next add μL ddH2O, mix and clarify.

Method for preparing in vivo formulation: Take μL DMSO master liquid, next add μL Corn oil, mix and clarify.

Note: 1. Please make sure the liquid is clear before adding the next solvent.
2. Be sure to add the solvent(s) in order. You must ensure that the solution obtained, in the previous addition, is a clear solution before proceeding to add the next solvent. Physical methods such as vortex, ultrasound or hot water bath can be used to aid dissolving.
3. All of the above co-solvents are available for purchase on the GlpBio website.

Product Documents

Quality Control & SDS

View current batch:

مراجعات

Review for Cal Green™ 1 AM

Average Rating: 5 ★★★★★ (Based on Reviews and 5 reference(s) in Google Scholar.)

5 Star
100%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%
Review for Cal Green™ 1 AM

GLPBIO products are for RESEARCH USE ONLY. Please make sure your review or question is research based.

Required fields are marked with *

You may receive emails regarding this submission. Any emails will include the ability to opt-out of future communications.