Inicio>>Signaling Pathways>> Membrane Transporter/Ion Channel>> Potassium Channel>>AUT1

AUT1

Catalog No.GC19480

AUT1 es un modulador de canal Kv3 humano recombinante.

Products are for research use only. Not for human use. We do not sell to patients.

AUT1 Chemical Structure

Cas No.: 1311136-84-1

Tamaño Precio Disponibilidad Cantidad
10mM (in 1mL DMSO)
94,00 $
Disponible
1mg
35,00 $
Disponible
5mg
86,00 $
Disponible
10mg
131,00 $
Disponible
50mg
349,00 $
Disponible
100mg
502,00 $
Disponible

Tel:(909) 407-4943 Email: sales@glpbio.com


Reseñas de cliente

Based on customer reviews.

  • GlpBio Citations

    GlpBio Citations
  • Bioactive Compounds Premium Provider

    Bioactive Compounds Premium Provider

Sample solution is provided at 25 µL, 10mM.

Description of AUT1

AUT1 (AUT-1) is a novel specific, cell permeant modulator of Kv3 channels with EC50 of 4.7 and 4.9 uM for Kv3.1b and Kv3.2a, respectively; displays approximately 10-fold lower potency for Kv3.3 channels, and does not interact with a wide range of ion channels, receptors, and transporters; increases hKv3.1b and hKv3.2a currents by 1049 ± 198% and 226 ± 39%, respectively, at 30 uM; rescue the fast firing capability of FS interneurons following a reduction in Kv3 channel availability, has the potential to rescue normal function and therapeutic benefit in disorders like schizophrenia or age-related cognitive decline.

Reference:

[1]. Rosato-Siri MD, et al. J Pharmacol Exp Ther. 2015 Sep;354(3):251-60.
[2]. Brown MR, et al. J Neurophysiol. 2016 Jul 1;116(1):106-21.
[3]. Parekh PK, et al. Neuropsychopharmacology. 2018 Jan;43(2):435-444.

Chemical Properties of AUT1

Cas No. 1311136-84-1 SDF
Chemical Name (5R)-5-ethyl-3-(6-{[4-methyl-3-(methyloxy)phenyl]oxy}-3-pyridinyl)-2,4-imidazolidinedione
Canonical SMILES O=C1N(C2=CC=C(OC3=CC=C(C)C(OC)=C3)N=C2)C([C@@H](CC)N1)=O
Formula C18H19N3O4 M.Wt 341.367
Solubility DMSO : ≥ 250 mg/mL (732.36 mM) Storage Store at -20°C
General tips Please select the appropriate solvent to prepare the stock solution according to the solubility of the product in different solvents; once the solution is prepared, please store it in separate packages to avoid product failure caused by repeated freezing and thawing.Storage method and period of the stock solution: When stored at -80°C, please use it within 6 months; when stored at -20°C, please use it within 1 month.
To increase solubility, heat the tube to 37°C and then oscillate in an ultrasonic bath for some time.
Shipping Condition Evaluation sample solution: shipped with blue ice. All other sizes available: with RT, or with Blue Ice upon request.

Complete Stock Solution Preparation Table of AUT1

Prepare stock solution
1 mg 5 mg 10 mg
1 mM 2.9294 mL 14.647 mL 29.294 mL
5 mM 0.5859 mL 2.9294 mL 5.8588 mL
10 mM 0.2929 mL 1.4647 mL 2.9294 mL
  • Molarity Calculator

  • Dilution Calculator

  • Molecular Weight Calculator

Mass
=
Concentration
x
Volume
x
MW*
 
 
 
**When preparing stock solutions always use the batch-specific molecular weight of the product found on the vial label and MSDS / CoA (available online).

Calculate

In vivo Formulation Calculator (Clear solution) of AUT1

Step 1: Enter information below (Recommended: An additional animal making an allowance for loss during the experiment)

mg/kg g μL

Step 2: Enter the in vivo formulation (This is only the calculator, not formulation. Please contact us first if there is no in vivo formulation at the solubility Section.)

% DMSO % % Tween 80 % ddH2O
%DMSO %

Calculation results:

Working concentration: mg/ml;

Method for preparing DMSO master liquid: mg drug pre-dissolved in μL DMSO ( Master liquid concentration mg/mL, Please contact us first if the concentration exceeds the DMSO solubility of the batch of drug. )

Method for preparing in vivo formulation: Take μL DMSO master liquid, next addμL PEG300, mix and clarify, next addμL Tween 80, mix and clarify, next add μL ddH2O, mix and clarify.

Method for preparing in vivo formulation: Take μL DMSO master liquid, next add μL Corn oil, mix and clarify.

Note: 1. Please make sure the liquid is clear before adding the next solvent.
2. Be sure to add the solvent(s) in order. You must ensure that the solution obtained, in the previous addition, is a clear solution before proceeding to add the next solvent. Physical methods such as vortex, ultrasound or hot water bath can be used to aid dissolving.
3. All of the above co-solvents are available for purchase on the GlpBio website.

Product Documents

Quality Control & SDS

View current batch:

Reseñas

Review for AUT1

Average Rating: 5 ★★★★★ (Based on Reviews and 34 reference(s) in Google Scholar.)

5 Star
100%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%
Review for AUT1

GLPBIO products are for RESEARCH USE ONLY. Please make sure your review or question is research based.

Required fields are marked with *

You may receive emails regarding this submission. Any emails will include the ability to opt-out of future communications.